Do not store or use gasoline or other flammable vapors and liquids in vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual
for future reference.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE
,
PERSONAL INJURY
,
OR LOSS OF LIFE.
PC-FBD32RT-1203
CAUTION – FOR YOUR SAFETY
Questions about installation, operation, or troubleshooting? Before returning to your retailer, contact our
customer service department at 1-877-886-5989, 8:00 a.m.- 4:30p.m., EST, Monday-Friday or e-mail
customerservice
@
usa
p
rocom.com.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air for Combustion and Ventilation section on page 7 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes. This appliance is only for use with
propane or natural gas. This appliance is equipped with a simple means to switch
between propane and natural gas. Field conversion by any other means including the
use of a kit is not
p
ermitted.
WARNING: This appliance is
equipped for (Natural and Propane)
gas. Field conversion is not
permitted other than between
natural or propane gases.
VENT-FREE GAS FIREPLACE INSERT
Model # FBD32RT
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - CAUTION – FOR YOUR SAFETY

– Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. WHAT TO DO I

Page 2 - MODEL FBD32RT

10 INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not inst

Page 3 - IMPORTANT SAFETY INFORMATION

11 NOTE: When heater is installed directly on carpeting, tile or other combustible material, other than wood flooring, the heater must be installed

Page 4

12 IMPORTANT: When finishing your firebox, Combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc, must have ½ -

Page 5

13 CONNECTING TO GAS SUPPLY WARNING: A qualified technician must connect heater to gas supply. Follow all local codes. WARNING: This appliance

Page 6

14 CAUTION: Use only new black iron or steel pipe. Internally tinned copper tubing may be used in certain areas. Check your local codes. Use pipe o

Page 7

15 CAUTION: Two gas line installations at the same time are prohibited. The access plate to the simple switching means shall not be opened while th

Page 8

16 CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks immediatel

Page 9

17 Installation for Decorative Trim: 1. Installation for Left/Right Decorative Trim:  Wedge two fl

Page 10

18 INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts included may result in

Page 11

19 STEP 7: Insert the pinhole on the upper part of log 7 in the pin on log 1, log 3 and log 5. STEP

Page 12

2 TABLE OF CONTENTS Important Safety Information ...

Page 13

20 OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result c

Page 14

21 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the front and back of the warning plate on page 20. 2. Make sure manual

Page 15

22 REMOTE CONTROL OPERATION MATCHING SECURITY CODES When matching security codes, be sure slide button on the receiver is in the REMOTE posit

Page 16

23 OFF OPERATION Press the OFF key and the appliance flame will shut off. During this time the LCD screen will show OF (figure 30). After 3 second

Page 17

24 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN 1. Turn control knob to pilot position 2. I

Page 18

25 CARE AND MAINTENANCE WARNING: Failure to keep primary air openings of burners clean may result in sooting and property damage. CAUTION: Yo

Page 19

26 TROUBLESHOOTING WARNING: If you smell gas:  Shut off gas supply.  Do not try to light any appliance.  Do not touch any electrical swi

Page 20

27 OBSERVED PROBLEM PROBABLE CAUSE REMEDY ODS/pilot lights but flame goes out w

Page 21

28 OBSERVED PROBLEM PROBABLE CAUSE REMEDY Slight smoke or odor during initial operati

Page 22 - REMOTE CONTROL OPERATION

29 REPLACEMENT PARTS NOTE: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS

Page 23

3 IMPORTANT SAFETY INFORMATION IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this he

Page 24

30 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts

Page 26 - TROUBLESHOOTING

32 WARRANTY INFORMATION Keep This Warranty IMPORTANT: We urge you to fill your warranty registration card within TEN (10) days of date of installat

Page 27

4 1. Do not place Propane/LP supply tank(s) inside any structure. Place Propane/LP supply tank(s) outdoors. 2. This heater needs fresh air ventil

Page 28

5 PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the

Page 29 - REPLACEMENT PARTS

6 UNPACKING 1. Remove top inner pack. 2. Tilt carton so that heater is upright. 3

Page 30 - PARTS LIST

7 AIR FOR COMBUSTION AND VENTILATION WARNING: If the area in which the heater may be operated does not meet the required volume for indoor combu

Page 31

8 2. Divide the space volume by 50 cu. ft. to determine the maximum BTU/hr the space can support. __________ (volume of space) ÷ 50 cu. ft.= (Max

Page 32 - WARRANTY INFORMATION

9 Ventilation Air From Inside Building This fresh air would come from adjoining unconfined space. When ventilating to an adjoining unconfined s